ReferenceChannels

Channels

Learn what channels are, what they are for, and how to choose a kind.

A channel is a named stream of time-ordered values from one source. Each value is a sample: one value at one point in time. A channel holds sensor readings, actuator commands, states, calculated values, or text. All data that you plot, record, or control in Synnax goes through a channel.

Synnax stores the samples of a channel and streams them live at the same time. A line plot shows each sample when it arrives, and you can read the same samples again later.

Read task
Script
Schematic button
Channel
Streamed liveplots, schematics, Arc
Storedranges, reads, exports
Read task
Script
Schematic button
Channel
Streamed liveplots, schematics, Arc
Storedranges, reads, exports

Channels are almost the same as tags in a SCADA system such as Ignition, or points in a historian such as AVEVA PI. A system can have thousands of channels, one for each data source.

What channels are for

Record sensor data

A read task samples the inputs of a device and writes each input to a data channel. The task also creates the index channel that holds the timestamps. You plot the channels live, and later you find the same data by range.

Command an actuator

A write task listens on a command channel, such as valve_1_cmd, and sends each value to the hardware. A valve on a schematic writes to that channel when you click it. A state channel, such as valve_1_state, shows what the hardware did.

Start an automation from a button

A schematic button writes 1 to a virtual channel, such as start_cmd. An Arc sequence starts when start_cmd receives 1. Nothing stores the button press, because only the live value is necessary.

Store data from a script

A script can create its own index and data channels, then write data to them. Use this for data from equipment that Synnax has no task for, or for results of an analysis.

Compute a value from other channels

A calculated channel computes its values from other channels. For example, return inlet_pressure - outlet_pressure gives the pressure drop across a filter. Synnax computes the values when you read the channel, so you do not store them.

Record events and notes

A data channel with the string or json data type stores text, such as operator notes or state changes. A log shows each value when it arrives.

Channel kinds

Each channel has one of four kinds. You select the kind when you create the channel, and you cannot change it later.

Kind Stores samples Index Values come from Use it to
Index Is an index A task or a script Hold the timestamps of data channels.
Data One index channel A task or a script Record sensor data, commands, or events.
Virtual None A task or a script Send a live signal that you do not need later.
Calculated One, that Synnax creates Synnax Compute a value from other channels.

Index channels

An index channel holds the timestamps for one or more data channels. Its data type is always timestamp: nanoseconds since the Unix epoch, in UTC.

An index channel works like the index of a book. To find the samples of a data channel in a time range, Synnax finds the timestamps in the index channel. Then it gets the samples at the same positions in the data channel. Here, one index channel holds the timestamps of two data channels:

tank_time (index) tank_pressure (data) tank_temperature (data)
2026-09-29T14:00:00.000000Z 101.2 21.4
2026-09-29T14:00:00.040000Z 101.5 21.4
2026-09-29T14:00:00.080000Z 102.1 21.5

Data channels that share an index share their timestamps. Each write gives one timestamp for each sample of all of these channels. Sensors that you sample at the same times can share an index. A command channel almost always needs its own index, because commands do not arrive at the same times as sensor samples.

Data channels

A data channel stores values, such as sensor readings, commands, or text. Each data channel has one data type and one index channel. You set both when you create the channel, and you cannot change them later.

Virtual channels

A virtual channel streams values live, and Synnax does not store them. A virtual channel has no index, and it cannot be an index. When you read a virtual channel over a past time range, you get no data. Use a virtual channel for a signal that only live views and automations use, such as a button press or a test value.

Calculated channels

A calculated channel computes its values from other channels with an Arc expression. Synnax does not store the values. It computes them when you stream or read the channel, for live data and for past time ranges. Synnax gives each calculated channel an index named <name>_time. See calculated channels.

Names

A channel name contains only letters, digits, and underscores, and it cannot start with a digit. Each name is unique, and names are case-sensitive. Arc automations and calculated channels use names to refer to channels, so a name must also be a valid Arc identifier.

These rules give names that are easy to find:

  • Use lowercase letters and underscores.
  • Put the system first, then the measurement: ox_tank_pressure, not pressure_ox_tank. Channels of one system then sort together.
  • Put the unit last when the channel has one: ox_tank_pressure_psi. Channels have no unit field.
  • Keep test and run facts out of names. Put them in ranges and their metadata.
Do not use Use Why
ai_0 ox_tank_pressure_psi The name tells what the channel measures.
pressure fuel_inlet_pressure A system usually has many pressure sensors.
OxTankPressure ox_tank_pressure One style makes names easy to type and match.
tc_3_hotfire_7 tc_3_degc One channel holds data from all runs. Ranges mark runs.

To show a different name for a channel during one test, give the channel an alias in a range.

Channels that tasks create

When you configure a task in the Console, the task creates its channels. The names start with the device identifier, such as dev1:

Task Channels Example names
Read task One index for each device, and one data channel for each input. dev1_ai_time, dev1_ai_0
Write task For each output, a command channel with its own index. dev1_ao_0_cmd, dev1_ao_0_cmd_time
Write task For each output that reports back, a state channel. All state channels of a device share one index. dev1_ao_0_state, dev1_ao_state_time

To use a different name, set the channel name in the task configuration. Modbus, OPC UA, and HTTP write tasks have no state channels. When you configure a task from Python or TypeScript, you create its channels yourself.

Channels in the Console

The channels toolbar shows all of the channels in Synnax. To open it, click its icon or press C.

  • Double-click a channel to add it to the open line plot, or to a new line plot. A virtual channel opens in a log.
  • Drag a channel onto a Y axis of a line plot, or onto a schematic.
  • Right-click a channel to rename it, delete it, or move it into a group. Groups only arrange the toolbar. They do not change the channel.
  • A calculated channel with an error shows a status icon. Hover over the icon to see the error.

The toolbar has buttons to create a channel and to create a calculated channel.

Frequently asked questions

Can I change the data type of a channel?

No. The data type, the kind, and the index of a channel stay the same for all of its life. Create a new channel with the correct settings, and send new data to it. The old channel keeps its data.

What happens when I rename a channel?

Plots, schematics, and tasks refer to channels by key, so they continue to work. Calculated channels and Arc automations refer to channels by name. Update them to use the new name. See rename channels.

Should I use a virtual channel or a calculated channel?

Use a virtual channel when a task, a script, or a button writes the values. Use a calculated channel when Synnax can compute the values from other channels.