Configure a LabJack device

Connect a LabJack T4 or T7 to the Driver and configure it for tasks.

The Driver connects to LabJack T4 and T7 devices over USB, Ethernet, or Wi-Fi. It finds them with the LabJack LJM library. Before a task can use a device, you configure it. The T8 is not supported yet.

Prerequisites

Supported
WindowsmacOS
Not supported
LinuxNI Linux RTDocker
  • Install the LJM library on the computer that runs the Driver, then restart the Driver.
  • Connect the device to that computer by USB, or to the same network.

How the Driver finds devices

The Driver looks for LabJack devices every few seconds. A USB device shows in the devices toolbar within a few seconds. A device on the network can take about a minute.

  • Name -> the model and the last four digits of the serial number, such as LJM_dtT7-8422.
  • Location -> the connection, such as LJM_ctUSB or LJM_ctETHERNET.

The Console also shows the notification “New LJM_dtT7 connected”, with a Configure button.

Configure a device

Enterprise
  1. In the devices toolbar, right-click the device and select Configure. You can also click Configure in the “New … connected” notification. To list each device that the Driver found, click and select LabJack hardware.
  2. Enter a Name and an Identifier, or click one of the identifiers that the Console suggests.
  3. Click Save. To also open a read task for the device, click Save and create read task.

Do not create LabJack devices in code. The Driver opens a device by its serial number, so only a device that the Driver found works in a task.

Troubleshooting

For other problems, see Troubleshoot hardware.